Difference between revisions of "Disable Logins Problem"

From VistApedia
Jump to: navigation, search
Line 5: Line 5:
 
This flag is part of the patch process, and is part of the system management for a VistA system.  Usually, a system manager has access to the system using programming mode, so it doesn't keep them from performing their work.
 
This flag is part of the patch process, and is part of the system management for a VistA system.  Usually, a system manager has access to the system using programming mode, so it doesn't keep them from performing their work.
  
To change this flag, the following dialog may be helpful, specifically the line marked in RED :
+
To change this flag, the following dialog may be helpful, specifically the line marked in RED :
 +
In this example the field's value is NO, but the message typically occurs when the value is YES. It can be changed simply by typing NO when prompted.
 
<pre>
 
<pre>
 
MUMPS>d Q^DI
 
MUMPS>d Q^DI
Line 19: Line 20:
 
VOLUME SET: EHR//
 
VOLUME SET: EHR//
 
TYPE: GENERAL PURPOSE VOLUME SET//</pre>
 
TYPE: GENERAL PURPOSE VOLUME SET//</pre>
<font color=red> INHIBIT LOGONS?: NO// </font><pre>
+
<font color=red> INHIBIT LOGONS?: </font> NO// <pre>
 
LINK ACCESS?: YES//
 
LINK ACCESS?: YES//
 
OUT OF SERVICE?: NO//
 
OUT OF SERVICE?: NO//
Line 30: Line 31:
  
 
</pre>
 
</pre>
 +
 +
 +
[[Category:HowTo]]

Revision as of 21:12, 21 September 2006

If you get a message like

"Sorry, all activity on this volume set is being halted!  Try again later."

then you probably have had the flag for disabling logins set.

This flag is part of the patch process, and is part of the system management for a VistA system. Usually, a system manager has access to the system using programming mode, so it doesn't keep them from performing their work.

To change this flag, the following dialog may be helpful, specifically the line marked in RED : In this example the field's value is NO, but the message typically occurs when the value is YES. It can be changed simply by typing NO when prompted.

MUMPS>d Q^DI
 
VA FileMan 22.0
 
Select OPTION: 1  ENTER OR EDIT FILE ENTRIES
 
INPUT TO WHAT FILE: VOLUME SET// volume set    (1 entry)
EDIT WHICH FIELD: ALL//
 
Select VOLUME SET: EHR
VOLUME SET: EHR//
TYPE: GENERAL PURPOSE VOLUME SET//
INHIBIT LOGONS?: NO//
LINK ACCESS?: YES//
OUT OF SERVICE?: NO//
REQUIRED VOLUME SET?: NO//
TASKMAN FILES UCI: EHR//
TASKMAN FILES VOLUME SET: EHR//
REPLACEMENT VOLUME SET:
DAYS TO KEEP OLD TASKS: 4//
SIGNON/PRODUCTION VOLUME SET: Yes//